HUBUNGAN LAMA PENGGUNAAN VENTILATOR DENGAN KEJADIAN VENTILATOR ASSOCIATED PNEUMONIARN(VAP) DI RUMAH SAKIT UMUM DAERAHRNDR. ZAINOEL ABIDIN BANDA ACEH
Description
ABSTRAKLatar Belakang : Ventilator Associated Pneumonia (VAP) adalah infeksi paru yang muncul setelah 48 jam intubasi endotrakeal dan ketika awal penggunaan Invasive Mechanical Ventilation (IMV). VAP merupakan infeksi nosokomial yang paling umum di Intensive Care Unit (ICU). Durasi penggunaan ventilator mekanik diidentifikasi sebagai salah satu faktor penting yang memicu VAP. Penelitian ini bertujuan untuk mengetahui hubungan antara lama penggunaan ventilator dengan kejadian Ventilator Associated Pneumonia (VAP) di Rumah Sakit dr. Zainoel Abidin (RSUDZA) Banda Aceh.Metode : Penelitian ini merupakan penelitian observasional analitik dengan menggunakan desain kohort. Pengambilan sampel dilakukan dengan metode accidental sampling di ICU menggunakan skor Clinical Pulmonary Infection Score (CPIS) pada pasien yang menggunakan ventilator mekanik lebih dari 48 jam di ICU Rumah Sakit dr. Zainoel Abidin (RSUDZA) Banda Aceh dari periode September - Oktober 2014. Jumlah sampel adalah 35 sampel. Data dideskripsikan dalam bentuk tabel dan gambar, dilakukan uji chi-square korelasi dengan SPSS.Hasil : Dari 35 sampel yang diperoleh, 17 orang (48,9%) terkena VAP dan 18 orang (51,4 %) pasien tidak terkena VAP. Hasil yang diperoleh uji chi-square p = 0,006 < 0.05.Kesimpulan : Ada hubungan antara lama penggunaan ventilator dengan kejadian Ventilator Associated Pneumonia (VAP) di Rumah Sakit dr. Zainoel Abidin (RSUDZA) Banda Aceh.Kata Kunci : Ventilator, Ventilator Associated Pneumonia (VAP)ABSTRACTBackground: Ventilator associated pneumonia (VAP) is a pulmonary infection that appears after 48 hours of endotracheal intubation and when invasive mechanical ventilation (IMV) is initially used. VAP is considered the most common nosocomial infection in the intensive care unit (ICU). The duration for using mechanical ventilator was identified as one of the important factors which is trigger of VAP. The aim of this study to the correlation between duration of using Mechanical ventilator with the case of ventilator associated pneumonia (VAP) in dr. Zainoel Abidin (RSUDZA) Hospital Banda Aceh. Methods: This study was an observational analytic study by using cohort design. Sampling was performed by accidental sampling method at the ICU using CPIS score of patients that using mechanical ventilator more than 48 hours at the ICU of the dr. Zainoel Abidin (RSUDZA) Hospital Banda Aceh from the period September to October 2014. The amount of sample was 35 samples. The data was described by form of tables and figures, and using chi-square correlation test with SPSS. Results: Out of 35 samples obtained, 17 persons (48,9 %) were hit by VAP and 18 persons (51,4%) patients were not hit by VAP. Results obtained Chi Square test p = 0.006 < 0.05. Conclusions: There was correlation between duration of using mechanical ventilators with the case of Ventilator Associated Pneumonia (VAP) in dr. Zainoel Abidin (RSUDZA) Hospital Banda Aceh.Keywords: Ventilator, Ventilator Associated Pneumonia (VAP)
Banda Aceh
Creator
maulidanur agustina
Publisher
Fakultas Kedokteran
Date
2015
Identifier
http://etd.unsyiah.ac.id//index.php?p=show_detail&id=11192